TLM500 components and oxygen transfer simulation
TLM500 components

Control cabinet
The cabinet houses the industrial PLC and the touch-screen operator panel (HMI). The operator selects process phases and monitors the process from this interface; the variables monitored and logged are defined in the project.
The equipment shown belongs to the TLM500 system; project scope varies by model.Oxygen transfer and uptake balance
The balance between oxygen transfer rate (OTR = kLa·(C* − C)) and oxygen uptake rate (OUR) is calculated with a simplified model for three scenarios. The model is for educational use and cannot replace a design calculation.
•••
Simulation and process data
The organism, target volume and any measured OUR or kLa values are sufficient to compare the simulated scenario with an existing process.